People who viewed this item also viewed
- -9%
- Accessories
- Fluke TL220 SureGripTM Industrial Test Lead Set
-
$121.00$110.00
- -1%
- Electronic Equipment, Multimeter
- Chauvin Arnoux CA 5231
-
$444.00$440.00
- -7%
- Industrial Test Equipment, Thermal Cameras
- Flir T1K HD Thermal Imaging Camera
-
$43,000.00$39,999.00
- -12%
- Multimeter
- Fluke 368 FC Leakage Current Clamp Meter
-
$1,290.00$1,133.00
- -40%
- Electrical Test Equipment, Relay Test Kit
- Doble F6150
-
$1,990.00$1,200.00Rated 5.00 out of 5
- -25%
- Electrical Test Equipment, SFRA, Transformer Testing
- Doble M5400
-
$1,600.00$1,200.00Rated 5.00 out of 5
Specifications
Description
Oxygen Probe BOT4
- Dissolved oxygen probe
- Membrane-covered polarographic Clark probe
- Built-in temperature sensor
- PVC body <-> more rugged in use
- Ideal for measurements in the laboratory, in the field or in industry
- Small diameter (only 12 mm),
- Used for measurements in small samples (e.g. beakers in laboratories)Dissolved oxygen probes comprise two precious-metal electrodesseparated by an electrolyte. Thus, the BOT4 probe has a platinum cathode soldered in glass and a silver anode. These two electrodes are immersed in a saline electrolytic solution (surfactant KCl). The probe is equipped with a membrane (PTFE film) which is permeable to oxygen.This membrane separates the electrodes and the saline electrolyte from the measurement environment. The oxygen diffuses through the membrane until it reaches the electrolyte where it is measured in dissolved form. The quantity of oxygen is proportional to the solution partial pressure.
The measurement itself is performed by applying a potential between the two electrodes. On the cathode, the following reduction occurs:O2 2H2O 4e– ↔ 4OH–While oxidization takes place on the anode:4Ag Cl– ↔ 4AgCl 4e–
The current produced is directly proportional to the dissolved oxygen concentration.
Calibration of the oxygen probe usually involves two phases. First, the probe is immersed in a solution of sulphite-enriched water in which the oxygen content is 0 mg/L. This allows you to adjust the instrument’s offset. The probe is then rinsed. It is then possible to adjust the slope either by placing the probe in ambient air and adjusting the value to 100%, or by immersing the probe in water with strong agitation and adjusting the value, this time expressed in mg/L, according to Mortimer’s table (which defines the solubility of oxygen in water in mg/L at a given pressure and temperature). The type of calibration will be chosen according to the medium (gas or liquid) in which the measurements will be performed.
The temperature and pressure significantly influence the concentration of dissolved oxygen. This means it is important to work at constant temperature and pressure. - Temperature compensation allowing work at temperatures between 25 and 35°C
- Faster response time than an optical sensor
- 5-pole DIN plug for adaptation to your instruments
Additional information
Weight | 0.02 kg |
---|---|
Dimensions | 12 x 1.2 cm |
Reviews
There are no reviews yet.
Explore more options
- -24%
- Voltage Detector
- Chauvin Arnoux C.A 757
-
$876.00$665.00Rated 5.00 out of 5
- Multimeter
- Chauvin Arnoux C.A 1052
- $3,150.00Rated 5.00 out of 5
- Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- $1,920.00Rated 4.00 out of 5
- Multimeter
- Chauvin Arnoux C.A 1866
- $889.00Rated 5.00 out of 5
- Calibration, Others
- Fluke 789 ProcessMeter™ with 250 Ohm HART resistor
- $1,100.00Rated 5.00 out of 5
- -23%
- Multimeter
- Chauvin Arnoux C.A 832
-
$998.00$765.00Rated 5.00 out of 5
Reviews
There are no reviews yet.